Midea Window Air Conditioner QB inverter / Midea U (MWAUQB CRFN8; MAW V1QWT series) EL0C Error Code

What the EL0C code means

Refrigerant leakage detection on Midea QB inverter window air conditioners (MWAUQB CRFN8 service manual; same inverter window platform as the Midea U MAW V1QWT series). Per the service manual, if the evaporator coil temperature T2 fails to drop at least 1°C below its compressor-start value (Tcool) for a continuous 4 seconds within the first 8 minutes after compressor start, three times in a row, the unit stops and displays EL0C.

Likely causes

  1. Refrigerant leak / low refrigerant charge in the sealed system
  2. Failed or loose T1/T2 temperature sensor connections skewing the detection
  3. Blockage in the refrigerant circuit
  4. Failed main PCB → Shop the main control board (pcb) at RepairClinic

How to fix it — step by step

  1. Turn the unit off and do not attempt any refrigerant work yourself
  2. Call a technician - the service manual's diagnosis checks the T1 and T2 sensor connections and substitutes a known-good T2 sensor, then checks for and repairs any leak and recharges the refrigerant if a leak is confirmed → Shop the evaporator temperature sensor (t2) at RepairClinic

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the EL0C code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.