Midea Window Air Conditioner QB inverter / Midea U (MWAUQB CRFN8; MAW V1QWT series) PH91 Error Code

What the PH91 code means

Low temperature protection of evaporator on Midea QB inverter window air conditioners (MWAUQB CRFN8 service manual; same inverter window platform as the Midea U MAW V1QWT series). The service manual notes this code is only displayed in engineer mode.

Likely causes

  1. Evaporator coil temperature too low / coil icing from restricted indoor airflow
  2. Dirty air filter
  3. Low refrigerant charge

How to fix it — step by step

  1. Turn the unit off, clean the air filter, and let any coil ice melt with the unit in Fan Only mode → Shop the air filter at RepairClinic
  2. Restart in Cool mode with an unobstructed indoor airflow path
  3. If the protection recurs, call a technician - persistent evaporator low-temperature protection can indicate a refrigerant or sensor fault → Shop the evaporator temperature sensor (t2) at RepairClinic

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the PH91 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Midea Window Air Conditioner QB inverter / Midea U (MWAUQB CRFN8; MAW V1QWT series) error codes

See all Midea QB inverter / Midea U (MWAUQB CRFN8; MAW V1QWT series) codes & guides →