Midea Window Air Conditioner QB inverter / Midea U (MWAUQB CRFN8; MAW V1QWT series) PH91 Error Code
What the PH91 code means
Low temperature protection of evaporator on Midea QB inverter window air conditioners (MWAUQB CRFN8 service manual; same inverter window platform as the Midea U MAW V1QWT series). The service manual notes this code is only displayed in engineer mode.
Likely causes
- Evaporator coil temperature too low / coil icing from restricted indoor airflow
- Dirty air filter
- Low refrigerant charge
How to fix it — step by step
- Turn the unit off, clean the air filter, and let any coil ice melt with the unit in Fan Only mode → Shop the air filter at RepairClinic
- Restart in Cool mode with an unobstructed indoor airflow path
- If the protection recurs, call a technician - persistent evaporator low-temperature protection can indicate a refrigerant or sensor fault → Shop the evaporator temperature sensor (t2) at RepairClinic
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the evaporator temperature sensor (T2).
Shop the evaporator temperature sensor (T2) at RepairClinic or Amazon
Also tied to this fault: air filter - Shop at RepairClinic or Amazon
Parts that commonly fix the PH91 code
- evaporator temperature sensor (T2) - Shop at RepairClinic or Amazon
- air filter - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.