Midea Window Air Conditioner QB inverter / Midea U (MWAUQB CRFN8; MAW V1QWT series) PC04 Error Code
What the PC04 code means
Inverter compressor drive error on Midea QB inverter window air conditioners (MWAUQB CRFN8 service manual; same inverter window platform as the Midea U MAW V1QWT series). Per the service manual, an abnormal inverter compressor drive is detected by a special detection circuit, including communication signal, voltage, and compressor rotation speed signal detection.
Likely causes
- Inverter drive fault on the PCB
- Failing compressor
How to fix it — step by step
- Power the unit off, then restart it once
- If the code returns, stop using the unit and call a technician - the service manual's diagnosis is to replace the PCB, and if the code still does not clear, replace the compressor → Shop the main control board (pcb) at RepairClinic → Shop the compressor at RepairClinic
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the main control board (PCB).
Shop the main control board (PCB) at RepairClinic or Amazon
Also tied to this fault: compressor - Shop at RepairClinic or Amazon
Parts that commonly fix the PC04 code
- main control board (PCB) - Shop at RepairClinic or Amazon
- compressor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Midea Window Air Conditioner QB inverter / Midea U (MWAUQB CRFN8; MAW V1QWT series) error codes
See all Midea QB inverter / Midea U (MWAUQB CRFN8; MAW V1QWT series) codes & guides →