What the F:24 code means

Inlet thermistor failure on Kenmore Elite dryers (110-series Whirlpool-built platform): the control detects a problem with the inlet temperature sensor, with F:24 listed for the open-circuit condition in service references for this platform.

Likely causes

  1. Failed inlet thermistor
  2. Loose or damaged inlet thermistor wiring
  3. Control board fault if sensor and wiring test good

How to fix it — step by step

  1. Unplug the dryer before any check
  2. Check the inlet thermistor wiring connections → Shop the thermistor at RepairClinic
  3. Test the thermistor resistance against the value in your tech sheet (about 10,000 ohms at room temperature on this platform)
  4. Replace the inlet thermistor if its resistance is out of range