Kenmore Dryer 110 Series (Whirlpool-Built) E1 Error Code

What the E1 code means

Thermistor failure on Kenmore 110-series dryers with electronic controls (Whirlpool-built platform): Sears PartsDirect lists E1 for this platform, and Whirlpool tech sheets for the platform describe E1 as the thermistor circuit open.

Likely causes

  1. Failed thermistor (temperature sensor)
  2. Open thermistor wiring
  3. Loose thermistor connection

How to fix it — step by step

  1. Unplug the dryer before any check
  2. Check the thermistor wiring and connections → Shop the thermistor at RepairClinic
  3. Test the thermistor resistance; it should measure about 10,000 ohms at room temperature
  4. Replace the thermistor if it is defective

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E1 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Kenmore manual is on Kenmore's support site — you'll need your model number.

Find your model number inside the door on the frame. It's the key to the right manual pages and the right parts.

Related Kenmore Dryer 110 Series (Whirlpool-Built) error codes

See all Kenmore 110 Series (Whirlpool-Built) codes & guides →