Friedrich Window Air Conditioner Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 17 codes covered.
Shop Friedrich Window Air Conditioner parts at RepairClinic or Amazon
All Window Air Conditioner codes across brands →
Finding your model number: it is on the unit's rating plate.
Kühl series (R-410A)
All Friedrich Kühl series (R-410A) codes & guides → (15 covered)
- 1 — Friedrich Kühl (R-410A) series error code 1, maintenance icon flashing: front panel button stuck for more than 20 seconds. Per the manual's…
- 11 — Friedrich Kühl (R-410A) series error code 11, maintenance icon on: WallStat problem or connection issue. Per the manual, a severity 4 error…
- 12 — Friedrich Kühl (R-410A) series error code 12, maintenance icon flashing: discharge air temperature greater than 185°F. Per the manual, the…
- 13 — Friedrich Kühl (R-410A) series error code 13, maintenance icon flashing: pressure limit switch open. Per the manual, if the unit is cooling…
- 14 — Friedrich Kühl (R-410A) series error code 14, maintenance icon flashing: discharge air temperature sensor is open or shorted. Per the…
- 15 — Friedrich Kühl (R-410A) series error code 15, maintenance icon solid on: heat pump error. Per the manual, this is set if the indoor coil…
- 16 — Friedrich Kühl (R-410A) series error code 16, maintenance icon flashing: temperature beyond operating limits - ambient temperature below…
- 17 — Friedrich Kühl (R-410A) series error code 17, maintenance icon flashing: equipment doesn't meet minimum configuration. Per the manual, the…
- 2 — Friedrich Kühl (R-410A) series error code 2, maintenance icon flashing: input voltage out of specification (103-127V / 187-253V). Per the…
- 24 — Friedrich Kühl (R-410A) series error code 24, maintenance icon flashing: outdoor air temperature sensor is open or shorted. Per the manual…
- 3 — Friedrich Kühl (R-410A) series error code 3, maintenance icon flashing: indoor temperature sensor is open or shorted. Per the manual, the…
- 4 — Friedrich Kühl (R-410A) series error code 4, maintenance icon flashing: indoor coil temperature sensor is open or shorted. Per the manual…
- 5 — Friedrich Kühl (R-410A) series error code 5, maintenance icon flashing: outdoor coil temperature sensor is open or shorted. Per the manual…
- 6 — Friedrich Kühl (R-410A) series error code 6, maintenance icon flashing: outdoor coil temperature greater than 175°F. Per the manual, the…
- 7 — Friedrich Kühl (R-410A) series error code 7, maintenance icon flashing: indoor coil temperature less than 30°F for 2 consecutive minutes…
Uni-Fit (UCT) / Chill Premier (CCW)
All Friedrich Uni-Fit (UCT) / Chill Premier (CCW) codes & guides → (2 covered)