Friedrich Window Air Conditioner Kühl series (R-410A) 2 Error Code

What the 2 code means

Friedrich Kühl (R-410A) series error code 2, maintenance icon flashing: input voltage out of specification (103-127V / 187-253V). Per the manual, the control board opens all relays until voltage is back within specification, then resumes operation.

Likely causes

  1. Supply voltage too low or too high
  2. Circuit overloaded by other appliances
  3. Utility power fluctuation

How to fix it — step by step

  1. Turn the unit off until supply power is stable and within the unit's rated range
  2. Make sure the unit is on its own dedicated circuit as specified in the manual
  3. If voltage problems persist, have an electrician check the supply - do not keep resetting the unit