Friedrich Window Air Conditioner Kühl series (R-410A) 6 Error Code

What the 6 code means

Friedrich Kühl (R-410A) series error code 6, maintenance icon flashing: outdoor coil temperature greater than 175°F. Per the manual, the unit shuts down for 5 minutes, resumes for 3 minutes, and continues to monitor; if the test fails 3 times the severity is increased and the unit is locked out.

Likely causes

  1. Dirty or blocked outdoor (condenser) coil restricting heat rejection
  2. Outdoor fan not moving enough air
  3. Refrigerant system fault causing excessive coil temperature

How to fix it — step by step

  1. Turn the unit off and clear any blockage from the outdoor side of the unit
  2. Clean the air filter and make sure airflow is unobstructed
  3. If the unit locks out after repeated failures, call a technician - repeated high coil temperature points to a fan or refrigerant-system fault

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 6 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Friedrich Window Air Conditioner Kühl series (R-410A) error codes

See all Friedrich Kühl series (R-410A) codes & guides →