Friedrich Window Air Conditioner Kühl series (R-410A) 3 Error Code

What the 3 code means

Friedrich Kühl (R-410A) series error code 3, maintenance icon flashing: indoor temperature sensor is open or shorted. Per the manual, the control board sets the temperature to 75°F in cooling or 68°F in heating and the unit continues to operate.

Likely causes

  1. Indoor temperature sensor open circuit or short circuit
  2. Loose sensor connection on the control board

How to fix it — step by step

  1. Note that the unit will keep running at the manual's default setpoints (75°F cooling / 68°F heating) while the fault is active
  2. Call a technician to test and replace the indoor temperature sensor or repair its connection → Shop the indoor temperature sensor at RepairClinic