Friedrich Window Air Conditioner Kühl series (R-410A) 13 Error Code

What the 13 code means

Friedrich Kühl (R-410A) series error code 13, maintenance icon flashing: pressure limit switch open. Per the manual, if the unit is cooling or the heat pump is on, the compressor shuts down and the fan runs at high speed until the switch closes, then operation resumes; the third occurrence in 1 hour locks the unit out.

Likely causes

  1. Refrigerant pressure outside safe limits tripping the pressure limit switch → Shop the pressure limit switch at RepairClinic
  2. Dirty or blocked condenser coil causing high pressure
  3. Failed pressure limit switch

How to fix it — step by step

  1. Turn the unit off and clear any blockage from the outdoor side; clean the air filter
  2. Restart once pressures have equalized
  3. If the unit locks out after a third occurrence in an hour, call a technician - pressure switch trips involve the sealed refrigerant system