Friedrich Window Air Conditioner Kühl series (R-410A) 13 Error Code
What the 13 code means
Friedrich Kühl (R-410A) series error code 13, maintenance icon flashing: pressure limit switch open. Per the manual, if the unit is cooling or the heat pump is on, the compressor shuts down and the fan runs at high speed until the switch closes, then operation resumes; the third occurrence in 1 hour locks the unit out.
Likely causes
- Refrigerant pressure outside safe limits tripping the pressure limit switch → Shop the pressure limit switch at RepairClinic
- Dirty or blocked condenser coil causing high pressure
- Failed pressure limit switch
How to fix it — step by step
- Turn the unit off and clear any blockage from the outdoor side; clean the air filter
- Restart once pressures have equalized
- If the unit locks out after a third occurrence in an hour, call a technician - pressure switch trips involve the sealed refrigerant system
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the pressure limit switch.
Parts that commonly fix the 13 code
- pressure limit switch - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.