What the E3 code means
E3 is actuation of the high pressure switch (HPS) — the safety switch has opened because refrigerant pressure on the high side went beyond its limit (SM-TS3; owner manuals phrase it 'high pressure protection'). It belongs to the models that carry a physical pressure switch; the documented causes are a dirty outdoor heat exchanger, a defective switch, clogged refrigerant piping, or a defective connector contact. The switch is a protection device doing its job or failing — either way, everything past the coil cleaning is refrigerant-circuit work.
Likely causes
- Dirty outdoor unit heat exchanger (SM-TS3's first cause)
- Defective high pressure switch
- Clogged refrigerant piping
- Defective connector contact at the switch
How to fix it — step by step
- Confirm E3 with the remote self-diagnosis, then do the one owner-level check that comes first: the outdoor heat exchanger. Breaker off, inspect the outdoor coil — a coil matted with cottonwood, dust or leaves cannot reject heat and drives head pressure up. Clean it gently (soft brush, low-pressure water from inside out) and clear anything blocking airflow around the unit
- Restore power and run cooling: if E3 stays away under load, the dirty coil was the cause
- If E3 returns with a clean coil and clear airflow, the remaining documented causes are inside the sealed system: a defective high pressure switch, clogged refrigerant piping, or a bad connector contact at the switch — all technician checks with gauges and the switch's continuity test
- Hand a shop this pinpoint: E3 confirmed, outdoor coil found clean (or cleaned), and whether the code trips immediately or only after sustained running — immediate trips lean switch/contact, load-dependent trips lean pressure/piping. Note for context: some Daikin pairs (FTXS/FDXS LV) have no pressure switch at all and implement this protection as F6 instead — if your unit shows F6 for the same behavior, F6 is the matching code
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the high pressure switch.
Parts that commonly fix the E3 code
- high pressure switch$50–$205Shop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) error codes
See all Daikin Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) codes & guides →