Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) E4 Error Code

What the E4 code means

E4 is actuation of the low pressure switch (LPS) — suction pressure has fallen below the safe limit (SM-TS3; owner manuals: 'low pressure protection'). It is the low-side counterpart to E3. Genuine low pressure usually means lost refrigerant or a restriction; the switch/sensor itself and its connector are the other documented causes. Because the confirming instruments are gauges on a sealed system, the owner portion is short: confirm the code, rule out the airflow and stop-valve basics, and hand over a clean pinpoint.

Likely causes

  1. Abnormally low pressure drop (refrigerant loss or restriction)
  2. Defective low pressure sensor/switch
  3. Defective outdoor unit PCB
  4. Defective connector contact

How to fix it — step by step

  1. Confirm E4 with the remote self-diagnosis. A low-pressure trip most often means the system is short of refrigerant or restricted — do not keep restarting it, as running a compressor starved of refrigerant return damages it
  2. Owner-level checks are limited but real: confirm the indoor filters and coil are clean and the indoor fan runs (starved indoor airflow collapses suction pressure), and confirm the outdoor unit's stop valves are fully open if the system was recently installed or serviced
  3. Everything else is the technician's: SM-TS3's causes are an abnormally low pressure drop, a defective low pressure sensor, a defective outdoor PCB, or a defective connector contact — separated with gauges, the sensor's continuity/output test, and a leak check if pressure is genuinely low
  4. Hand a shop this pinpoint: E4 confirmed, indoor airflow verified, and whether the trip happens at start-up (leans sensor/contact) or after running (leans genuine low pressure). Context note: the FTXS/FDXS LV pair has no low pressure switch and folds this protection into its sensor-based controls — E4 belongs to the unified-table models that carry the switch/sensor

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E4 code

Typical pro repair $450–$2,000
  • low pressure switch$50–$205Shop at Amazon
  • Tools for this job, if you need them$15–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) error codes

See all Daikin Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) codes & guides →