Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) H0 Error Code
What the H0 code means
H0 is a compressor system sensor abnormality — a summary code the outdoor control sets when one of the sensors it monitors around the compressor system reads out of range (operation manual wording is simply 'sensor fault'). SM-TS3: 'malfunction of sensor system of compressor.' It is a group diagnosis rather than a single named sensor, which is why the fix flow is a connector-and-resistance sweep of the outdoor thermistor group before the board is suspected.
Likely causes
- Defective sensor in the compressor system (thermistor group)
- Disconnected sensor connector
- Defective outdoor unit PCB reading the sensors
How to fix it — step by step
- Confirm H0 with the remote self-diagnosis
- Breaker off; at the outdoor unit, check the compressor-area sensor connectors (the thermistor group the board monitors) for seating, corrosion and damaged leads — a disconnected sensor is the cheapest version of this code
- Test the thermistors against Daikin's resistance chart (Check No. 01 method: about 20 kΩ at 25°C for these sensors): any sensor open, shorted or far off chart is replaced
- If all sensors conform and connectors are sound, the outdoor PCB is misreading them — the documented remainder. Hand a shop the pinpoint with any resistance readings taken
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the discharge pipe thermistor.
Shop the discharge pipe thermistor at Amazon
Also tied to this fault: outdoor unit PCB - Shop at Amazon
Parts that commonly fix the H0 code
- discharge pipe thermistor$25–$80Shop at Amazon
- outdoor unit PCB$80–$400Shop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
Before you buy: check the discharge pipe thermistor first
Test: Disconnect the thermistor's connector from the PCB and measure its resistance at the sensor's actual temperature (Daikin service manual SiUS091133, Check No. 01).
A good one reads: About 20 kΩ at 25 °C (77 °F); 25 kΩ at 20 °C; 16.1 kΩ at 30 °C; 65.9 kΩ at 0 °C; 10.6 kΩ at 40 °C. Open, shorted or far off the chart means the thermistor has failed.
Test values from manualshelf.com documentation - confirm against your model's own tech sheet.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) error codes
See all Daikin Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) codes & guides →