What the E8 code means
E8 is input overcurrent detection (service manual SiUS091133; SM-TS3: 'overcurrent of inverter compressor'). The outdoor control has measured the system's input current beyond its limit and stopped operation to protect the inverter and compressor. It is a measurement of the whole outdoor unit's appetite, so the cause sits with the compressor's load, the compressor itself, or the board doing the measuring — all sealed-system/inverter territory after the basic external checks.
Likely causes
- Inverter compressor drawing excess current (mechanical load, failing compressor)
- Defective outdoor unit PCB current detection
- Supply or wiring problem feeding the outdoor unit
How to fix it — step by step
- Confirm E8 with the remote self-diagnosis. Do not repeatedly restart: an overcurrent detection means the inverter is already limiting a compressor that is drawing too much
- Breaker off; inspect the outdoor unit for the mechanical contributors you can see — a blocked outdoor fan or a matted coil makes the compressor work harder (a fan fault usually sets E7 first, but verify the fan spins freely by hand)
- Check the compressor harness connections at the outdoor board for seating and heat damage
- Beyond this the checks are the technician's: input current measurement against the model's specification separates a genuinely over-drawing compressor from a board misreading current. Hand over the pinpoint: E8 confirmed, fan and coil verified, harness seated
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the outdoor unit PCB.
Shop the outdoor unit PCB at Amazon
Also tied to this fault: compressor - Shop at Amazon
Parts that commonly fix the E8 code
- outdoor unit PCB$80–$400Shop at Amazon
- compressor$400–$1,500Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) error codes
See all Daikin Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) codes & guides →