Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) H1 Error Code
What the H1 code means
H1 carries a dual definition in SM-TS3: a malfunction of the room temperature sensor, or of a humidifier unit damper, depending on the system family the chart row serves. On residential ductless units the room-sensor reading is the applicable one where the code is used; it is not the indoor C9 sensor (that is the indoor unit's own room thermistor) — H1 belongs to the outdoor/system side of the chart. Because this code has two definitions, treat the flow below as the sensor flow and note the ambiguity when handing it over. This code belongs to Daikin's unified residential ductless malfunction table (SM-TS3), shared across the FTXS/FDXS/FTXM/RMXS families; pull it with the remote self-diagnosis before acting on it.
Likely causes
- Defective room temperature sensor (applicable systems)
- Sensor connector disconnected
- Defective control PCB reading the sensor
How to fix it — step by step
- Confirm the code with the remote self-diagnosis first (hold TIMER CANCEL for 5 seconds until 00 shows, then press it repeatedly until the long beep marks the stored code)
- Breaker off. Check the applicable sensor's connector for seating and damage — disconnection heads the causes for every Daikin sensor code
- Test the sensor against the thermistor chart where it is a thermistor (about 20 kΩ at 25°C): off-chart condemns the sensor
- If the sensor conforms and is connected, the reading board is the remainder — hand a shop the pinpoint, and state plainly that SM-TS3 gives H1 two definitions (room sensor / humidifier damper) so the technician starts from your model's own chart
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the room temperature sensor.
Shop the room temperature sensor at Amazon
Also tied to this fault: outdoor unit PCB - Shop at Amazon
Parts that commonly fix the H1 code
- room temperature sensor$25–$80Shop at Amazon
- outdoor unit PCB$80–$400Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) error codes
See all Daikin Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) codes & guides →