Crown Boiler Boiler Phantom-X series (PHNTM) Soft Lockout 9
What this problem usually means
Phantom-X soft lockout 9 is a DHW sensor fault: the domestic hot water temperature sensor is shorted or open. Heating may be unaffected, but the boiler cannot control or protect the hot water side, so it soft-locks the DHW function until the sensor reads correctly.
Likely causes
- Shorted or open DHW temperature sensor
- Shorted or miswired DHW sensor wiring
- Defective DHW sensor
How to fix it — step by step
- Record the code before resetting anything: write down the display exactly as shown (Soft Lockout 9) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
- Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
- Locate the part: the DHW sensor is on the hot water outlet/indirect connection; its status shows on the Help screen's Sensor Status page.
- Test: read the DHW sensor on Sensor Status and inspect its harness. An open or impossible reading with a continuous, unshorted harness condemns the sensor.
- End at the pinpoint: repair the wiring or replace the DHW temperature sensor as condemned. The boiler restarts automatically once the reading is valid. Technician work. → Shop the temperature sensor at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Temperature sensor.
Parts that commonly fix it
- Temperature sensor$25–$80Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.
Related Crown Boiler Boiler Phantom-X series (PHNTM) problems
- Hard Lockout 12
- Hard Lockout 18
- Hard Lockout 23
- Hard Lockout 27
- Hard Lockout 4
- Hard Lockout 6
- Soft Lockout 10
- Soft Lockout 11
- Soft Lockout 13
- Soft Lockout 14
- Soft Lockout 15
- Soft Lockout 16
See all Crown Boiler Phantom-X series (PHNTM) codes & guides →