Crown Boiler Boiler Phantom-X series (PHNTM) Hard Lockout 23

What this problem usually means

Phantom-X hard lockout 23 means the R7910 control's 24 VAC control power is high or low. The manual's causes are a loose connection in the 120 VAC/24 VAC power wiring, a loose or miswired 24 VAC harness, miswired harness causing a power supply short to ground, a defective transformer, and a transformer whose frequency, voltage, and VA do not meet specification. A hard lockout needs a manual reset.

Likely causes

  1. 24 VAC control power high or low
  2. Loose connection in 120 VAC or 24 VAC power wiring
  3. Miswired harness shorting the power supply to ground
  4. Defective transformer
  5. Transformer frequency/voltage/VA out of specification

How to fix it — step by step

  1. Record the code before resetting anything: write down the display exactly as shown (Hard Lockout 23) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
  2. Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
  3. Locate the part: the transformer and the 24 VAC harness between the transformer and the R7910 control, inside the control compartment.
  4. Test: measure the 24 VAC at the control and compare with the transformer output. Correct transformer output with low voltage at the control condemns the harness or a short to ground; wrong output at the transformer condemns the transformer.
  5. End at the pinpoint: replace the Transformer or repair the harness/short as the measurements direct, then reset manually. Technician work. → Shop the transformer at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.