What this problem usually means
Phantom-X soft lockout 10 is a stack sensor fault: the flue gas (stack) temperature sensor is shorted or open. The boiler uses stack temperature as a safety and efficiency input, so it soft-locks until the sensor reads correctly. Shorted or miswired wiring and a defective sensor are the listed causes.
Likely causes
- Shorted or open stack (flue gas) temperature sensor
- Shorted or miswired stack sensor wiring
- Defective stack sensor
How to fix it — step by step
- Record the code before resetting anything: write down the display exactly as shown (Soft Lockout 10) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
- Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
- Locate the part: the stack sensor is in the flue outlet at the top of the boiler; its reading and status show on the Help screen's Sensor Status page.
- Test: check the stack reading on Sensor Status against reality (a cold boiler should read near room temperature). An impossible reading with a sound harness condemns the sensor. → Shop the temperature sensor at Amazon
- End at the pinpoint: repair the wiring or replace the Stack temperature sensor as condemned. The boiler restarts on its own once the reading is valid. Technician work.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Temperature sensor.
Parts that commonly fix it
- Temperature sensor$25–$80Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.
Related Crown Boiler Boiler Phantom-X series (PHNTM) problems
- Soft Lockout 11
- Soft Lockout 13
- Soft Lockout 14
- Soft Lockout 15
- Soft Lockout 16
- Soft Lockout 2
- Soft Lockout 3
- Soft Lockout 7
- Soft Lockout 8
- Soft Lockout 9
- Hard Lockout 12
- Hard Lockout 18
See all Crown Boiler Phantom-X series (PHNTM) codes & guides →