Crown Boiler Boiler Phantom-X series (PHNTM) Soft Lockout 13
What this problem usually means
Phantom-X soft lockout 13 means the flame rod is shorted to ground. The control sees a grounded flame rod and cannot trust any flame signal from it, so it soft-locks. Shorted or miswired flame rod wiring and a defective flame rod are the listed causes.
Likely causes
- Flame rod shorted to ground
- Shorted or miswired flame rod wiring
- Defective flame rod
How to fix it — step by step
- Record the code before resetting anything: write down the display exactly as shown (Soft Lockout 13) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
- Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
- Locate the part: the flame rod is at the burner, beside the electrode; trace its lead back to the R7910 control for contact points against the burner or jacket.
- Test: inspect the rod for contact with burner metal and the lead for chafed insulation. A rod and lead that are visibly clear but still read grounded condemn the flame rod itself.
- End at the pinpoint: clear the short or repair the wiring, or replace the Flame rod if it is defective. The boiler restarts automatically once the short is gone. Technician work. → Shop the flame rod at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Flame rod.
Parts that commonly fix it
- Flame rod$10–$60Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.
Related Crown Boiler Boiler Phantom-X series (PHNTM) problems
- Soft Lockout 14
- Soft Lockout 15
- Soft Lockout 16
- Soft Lockout 2
- Soft Lockout 3
- Soft Lockout 7
- Soft Lockout 8
- Soft Lockout 9
- Hard Lockout 12
- Hard Lockout 18
- Hard Lockout 23
- Hard Lockout 27
See all Crown Boiler Phantom-X series (PHNTM) codes & guides →