Crown Boiler Phantom-X series (PHNTM) Common Problems

Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 17 problems covered.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

ProblemWhat it meansCheck first
Hard Lockout 12Phantom-X hard lockout 12 means a flame signal was present when there should be no flame: flame detected out…Flame signal present with no flame expected›
Hard Lockout 18Phantom-X hard lockout 18 means light-off rate proving failed: the blower is not running at light-off rate…Loose connection in 120 VAC blower wiring›
Hard Lockout 23Phantom-X hard lockout 23 means the R7910 control's 24 VAC control power is high or low. The manual's causes…24 VAC control power high or low›
Hard Lockout 27Phantom-X hard lockout 27 is ignition failure on the larger models: on model PHNTM500, flame failure after 1…No gas pressure, or pressure under the rating-plate minimum›
Hard Lockout 4Phantom-X hard lockout 4 is Supply High Limit: the R7910 supply sensor detected temperatures in excess of 200…Heating load far below the boiler minimum firing rate›
Hard Lockout 6Phantom-X hard lockout 6 is Stack High Limit: the R7910 flue gas (stack) sensor detected temperatures in…Stack temperature above 572 F (300 C)›
Soft Lockout 10Phantom-X soft lockout 10 is a stack sensor fault: the flue gas (stack) temperature sensor is shorted or…Shorted or open stack (flue gas) temperature sensor›
Soft Lockout 11Phantom-X soft lockout 11 is ignition failure: on model PH170, flame failure after 3 tries to restart (the…No gas pressure, or pressure under the rating-plate minimum›
Soft Lockout 13Phantom-X soft lockout 13 means the flame rod is shorted to ground. The control sees a grounded flame rod and…Flame rod shorted to ground›
Soft Lockout 14Phantom-X soft lockout 14 is DT inlet/outlet high: the temperature rise between supply and return is too…Inadequate boiler water flow›
Soft Lockout 15Phantom-X soft lockout 15 means the control is reading a return sensor temperature higher than the supply…Return temperature higher than supply for at least 60 seconds›
Soft Lockout 16Phantom-X soft lockout 16 means the supply water temperature has risen too quickly. The manual ties it to the…Supply temperature rising too quickly›
Soft Lockout 2Phantom-X soft lockout 2 means a Boiler Safety Limit wired to the control has opened. The manual groups the…Condensate trap float switch contact open (plugged condensate trap)›
Soft Lockout 3Phantom-X soft lockout 3 means the Boiler Safety Limit or External Limit circuit wired to terminals J5-1 (and…External limit device open or defective›
Soft Lockout 7Phantom-X soft lockout 7 is a return sensor fault: the return temperature sensor is shorted or open. The…Shorted or open return temperature sensor›
Soft Lockout 8Phantom-X soft lockout 8 is a supply sensor fault: the supply temperature sensor is shorted or open. Supply…Shorted or open supply temperature sensor›
Soft Lockout 9Phantom-X soft lockout 9 is a DHW sensor fault: the domestic hot water temperature sensor is shorted or open.…Shorted or open DHW temperature sensor›