Crown Boiler Boiler Phantom-X series (PHNTM) Hard Lockout 6

What this problem usually means

Phantom-X hard lockout 6 is Stack High Limit: the R7910 flue gas (stack) sensor detected temperatures in excess of 572 F (300 C). The manual's causes are a heat exchanger that needs cleaning and a boiler that is overfired, including an air/fuel mixture out of adjustment. A hard lockout needs a manual reset after the cause is corrected.

Likely causes

  1. Stack temperature above 572 F (300 C)
  2. Heat exchanger needs cleaning
  3. Boiler overfired
  4. Air/fuel mixture out of adjustment

How to fix it — step by step

  1. Record the code before resetting anything: write down the display exactly as shown (Hard Lockout 6) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
  2. Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
  3. Locate the part: the stack sensor is in the flue outlet; the heat exchanger is behind the burner door, and its condition is the first physical check.
  4. Test: inspect the heat exchanger for fouling that would force flue temperatures up, and verify the firing rate and mixture with combustion testing. A clean exchanger at correct input with a still-high reading sends the check to the stack sensor itself.
  5. End at the pinpoint: clean the Heat exchanger or correct the overfire/mixture (factory-consult work per the manual), then reset manually. Technician work only.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Crown Boiler Boiler Phantom-X series (PHNTM) problems

See all Crown Boiler Phantom-X series (PHNTM) codes & guides →