Carrier Air Conditioner 16 Error Code

What the 16 code means

System communications failure, read as short/long flashes of the amber LED on the outdoor unit control board of a Carrier Infinity 24ANA two-stage air conditioner (also shown on the Infinity user interface). Communication with the user interface has been lost.

Likely causes

  1. Damaged or loose ABCD communicating wiring between the user interface, indoor unit and outdoor unit
  2. Incorrect communicating wiring connections
  3. Failed outdoor control board or user interface

How to fix it — step by step

  1. Turn off power to the indoor and outdoor units
  2. Check the ABCD communicating wiring at the user interface, indoor unit and outdoor unit for loose or damaged connections
  3. Restore power and check whether communication is re-established
  4. If the code returns, have a technician test the communicating circuit and controls

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 16 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Carrier manual is on Carrier's support site — you'll need your model number.

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Carrier Air Conditioner error codes