Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 19 codes covered.
Shop Carrier Air Conditioner parts at RepairClinic or Amazon
All Air Conditioner codes across brands →
Finding your model number: it is on the unit's rating plate.
- 16 — System communications failure, read as short/long flashes of the amber LED on the outdoor unit control board of a Carrier Infinity 24ANA…
- 47 — No 230V at the unit, read as short/long flashes of the amber LED on the outdoor unit control board of a Carrier Infinity 24ANA two-stage…
- 53 — Outdoor air temperature sensor fault, read as short/long flashes of the amber LED on the outdoor unit control board of a Carrier Infinity…
- 55 — Outdoor coil sensor fault, read as short/long flashes of the amber LED on the outdoor unit control board of a Carrier Infinity 24ANA…
- 56 — Thermistors out of range, read as short/long flashes of the amber LED on the outdoor unit control board of a Carrier Infinity 24ANA…
- 71 — Low-stage thermal cutout, read as short/long flashes of the amber LED on the outdoor unit control board of a Carrier Infinity 24ANA…
- 72 — High-stage thermal cutout, read as short/long flashes of the amber LED on the outdoor unit control board of a Carrier Infinity 24ANA…
- 73 — Contactor shorted, read as short/long flashes of the amber LED on the outdoor unit control board of a Carrier Infinity 24ANA two-stage air…
- 74 — No 230V at the compressor, read as short/long flashes of the amber LED on the outdoor unit control board of a Carrier Infinity 24ANA1 air…
- 81 — Low-stage thermal lockout, read as short/long flashes of the amber LED on the outdoor unit control board of a Carrier Infinity 24ANA…
- 83 — Low pressure lockout, read as short/long flashes of the amber LED on the outdoor unit control board of a Carrier Infinity 24ANA two-stage…
- 84 — High pressure lockout, read as short/long flashes of the amber LED on the outdoor unit control board of a Carrier Infinity 24ANA two-stage…
- 85 — Low-stage contactor open, read as short/long flashes of the amber LED on the outdoor unit control board of a Carrier Infinity 24ANA7…
- AC leaking water inside — All the moisture a Carrier system pulls from indoor air condenses on the evaporator coil, drips into a drain pan, and should leave through…
- AC not cooling — When a Carrier split system runs but the house does not get cooler, Carrier's own troubleshooting sequence puts settings and airflow first…
- AC short cycling — Short cycling is the system turning on and off repeatedly without completing a full cooling cycle — Carrier flags cycles repeating roughly…
- AC won't turn on — A Carrier system that will not start at all is most often suffering a power or control interruption rather than a dead compressor.…
- Condenser fan not spinning — The outdoor fan pulls air across the condenser coil so the heat collected indoors can be dumped outside. Carrier identifies four leading…
- Frozen evaporator coil — The indoor evaporator coil absorbs heat from house air, and Carrier notes it freezes when airflow over it is restricted or refrigerant runs…