What the 47 code means

No 230V at the unit, read as short/long flashes of the amber LED on the outdoor unit control board of a Carrier Infinity 24ANA two-stage air conditioner. There is no 230V at the contactor even though the indoor unit is powered and a cooling/heating demand exists.

Likely causes

  1. Outdoor disconnect switch open or pulled → Shop the outdoor disconnect switch at RepairClinic
  2. Tripped breaker or blown fuse for the outdoor unit
  3. 230V wiring not connected to the unit

How to fix it — step by step

  1. Check the outdoor unit breaker in the electrical panel and reset it if tripped
  2. Check that the outdoor disconnect next to the unit is closed / fully inserted
  3. If power is present at the disconnect but the code remains, have a technician verify the 230V wiring to the unit

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 47 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Carrier manual is on Carrier's support site — you'll need your model number.

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Carrier Air Conditioner error codes