Carrier Air Conditioner 83 Error Code

What the 83 code means

Low pressure lockout, read as short/long flashes of the amber LED on the outdoor unit control board of a Carrier Infinity 24ANA two-stage air conditioner. A low pressure switch trip occurred during three consecutive cycles; operation is locked out for 4 hours or until 24V power is recycled.

Likely causes

  1. Low refrigerant charge / refrigerant leak
  2. Restriction in the refrigerant circuit
  3. Low indoor airflow (dirty filter, blower problem) causing low suction pressure

How to fix it — step by step

  1. Replace a dirty indoor air filter and confirm the indoor blower runs
  2. Turn the system off rather than repeatedly resetting the lockout
  3. Have a technician check refrigerant pressures, find any leak and verify charge

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 83 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.