Carrier Air Conditioner 56 Error Code

What the 56 code means

Thermistors out of range, read as short/long flashes of the amber LED on the outdoor unit control board of a Carrier Infinity 24ANA two-stage air conditioner. The control sees an improper relationship between the outdoor coil sensor and the outdoor air sensor readings.

Likely causes

  1. One of the two thermistors drifting out of calibration
  2. Sensor wiring fault or sensors swapped / incorrectly located
  3. Failed outdoor control board sensor input

How to fix it — step by step

  1. Turn off power to the outdoor unit
  2. Have a technician ohm out both the coil and outdoor air sensors and compare them with the chart
  3. Replace the out-of-range sensor and verify sensor placement and wiring

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 56 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Carrier manual is on Carrier's support site — you'll need your model number.

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Carrier Air Conditioner error codes

See all Carrier Air Conditioner codes & guides →