Ruud Furnace 801S Series (7 segment display control) 93 Error Code

What the 93 code means

Internal control fault. The control has found a fault inside itself, or it senses voltage on the gas valve circuit that should not be there. This is a hard lockout.

Likely causes

  1. Internal fault inside the furnace control
  2. Voltage sensed on the gas valve circuit from a welded relay contact on the control

How to fix it — step by step

  1. This is a hard lockout. Cycling the heat call will not clear it.
  2. Turn the power off for a full minute, then restore it. If code 93 returns at once, the fault is inside the control.
  3. Do not keep resetting. The manual ties this code to an internal control fault or a welded gas valve relay, and both end at the control board.
  4. Call a pro to confirm voltage at the gas valve circuit and replace the furnace control. There is no field repair for the board itself.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 93 code

Typical pro repair $200–$600

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.