Ruud Furnace 801S Series (7 segment display control) 10 Error Code

What the 10 code means

One hour lockout. The control has stopped heating for one hour after a repeated ignition, flame, or blower fault. The display alternates 10 with the code for the fault that caused it.

Likely causes

  1. Repeated failed ignition locked the control out
  2. Flame lost five times in one call locked the control out
  3. Unexpected flame detected
  4. Dead blower with the main limit open for over 150 seconds

How to fix it — step by step

  1. Read the display. Code 10 shows together with a second code such as 11, 13, 14, or 61, and the second code names the real fault. Diagnose that code first.
  2. Turn the power off, fix the cause shown by the paired code, then restore power. A soft lockout also clears if the heat call is cycled off for more than 2 seconds but less than 20 seconds.
  3. Do not just reset and walk away. A lockout that returns on the next call means the paired fault is still present.
  4. Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - 10 should stay clear for the whole cycle. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 10 code

No specific replacement part is documented for this fault. If the checks above do not clear it, your furnace likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related Ruud Furnace 801S Series (7 segment display control) error codes

See all Ruud 801S Series (7 segment display control) codes & guides →