Ruud Furnace Error Codes

Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 13 codes covered.

Finding your model number: it is inside the blower/burner compartment door.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

801S Series (7 segment display control)

CodeWhat it meansCheck first
10One hour lockout. The control has stopped heating for one hour after a repeated ignition, flame, or blower…Repeated failed ignition locked the control out›
11Failed ignition. The furnace made its ignition tries and never proved flame. Four failed tries in a row put…Gas supply off or low gas pressure›
12Low flame sense. The flame signal reaching the control is weak. The furnace may still run, but the signal is…Flame sensor coated or oxidized›
13Flame lost. Flame was proved, then lost during the heating cycle. Five losses in one heat call put the…Dirty flame sensor losing the signal mid cycle›
14Unexpected flame. The control senses flame when the gas valve should be off. The control locks out for one…Gas valve leaking through or closing slowly›
20Twinning fault. On a twinned installation, where two furnaces share one duct system and thermostat, the…Two furnaces twinned to one duct system with mismatched control settings›
22Main limit open. The main high limit switch opened because the furnace overheated, most often from low…Dirty air filter choking airflow›
26Line and neutral reversed. The 120 volt supply to the furnace is wired with line and neutral swapped.Line and neutral swapped at the furnace junction box›
33Manual reset limit control open, also called the rollout switch. Flame or excess heat escaped the burner area…Flame rollout from a blocked vent›
55Pressure switch stuck closed when it should be open. The control checks the switch before the inducer starts…Pressure switch contacts stuck or welded closed›
57Pressure switch stuck open when it should be closed. The inducer runs but the switch never proves draft, so…Blocked vent or intake pipe›
61Blower fault. The blower is unable to run. The control declares a dead blower when the main limit stays open…Blower motor failed›
93Internal control fault. The control has found a fault inside itself, or it senses voltage on the gas valve…Internal fault inside the furnace control›