Ruud Furnace 801S Series (7 segment display control) 33 Error Code
What the 33 code means
Manual reset limit control open, also called the rollout switch. Flame or excess heat escaped the burner area and tripped a switch that only resets by hand.
Likely causes
- Flame rollout from a blocked vent
- Failed induced draft blower
- Cracked heat exchanger pushing flame out of the burners
- Faulty manual reset limit switch
How to fix it — step by step
- Turn the power off and close the gas shutoff. Do not reset this switch and restart the furnace until you know why it opened. This switch trips when flame escapes the burner compartment.
- Look above the burners for scorch marks, melted insulation, or a soot trail. Any of these confirms real rollout.
- Check the full vent run and the outdoor termination for blockage, and confirm the inducer runs when power is restored for a test call.
- Find the manual reset limit above the burners and test it with a meter once cool. A switch that reads open after the vent and inducer check out may itself have failed. → Shop the manual reset limit switch at Amazon
- If rollout damage is visible or the switch trips again, stop. A pro must check the heat exchanger before this furnace runs again.
- Verify the fix: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - 33 should stay clear for the whole cycle. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the manual reset limit switch.
Parts that commonly fix the 33 code
- manual reset limit switch$5–$35Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.