Ruud Furnace 801S Series (7 segment display control) 11 Error Code

What the 11 code means

Failed ignition. The furnace made its ignition tries and never proved flame. Four failed tries in a row put the control into the one hour lockout, shown as codes 10 and 11 together.

Likely causes

  1. Gas supply off or low gas pressure
  2. Failed or cracked hot surface igniter
  3. Dirty flame sensor so flame is lit but not proved
  4. Faulty gas valve not opening

How to fix it — step by step

  1. Turn the power off and close the gas shutoff before working inside the furnace.
  2. Confirm the gas shutoff to the furnace is open and other gas appliances work. No gas anywhere is a supply problem, not a furnace part.
  3. Remove the burner door and find the igniter in front of the burners. Check it for cracks. Restore power and call for heat. An igniter that never glows has failed or has no power.
  4. If the igniter glows and the burners light then drop out, turn the power off and clean the flame sensor rod with fine steel wool. The sensor is the single rod in the flame path.
  5. If the igniter glows, no gas flows, and the valve clicks with 24 volts present, the gas valve has failed. Gas valve replacement is pro work. → Shop the gas valve at Amazon
  6. Verify the fix: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - 11 should stay clear for the whole cycle. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 11 code

Typical pro repair $150–$500

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.