Ruud Furnace 801S Series (7 segment display control) 14 Error Code

What the 14 code means

Unexpected flame. The control senses flame when the gas valve should be off. The control locks out for one hour after the flame signal goes away, showing codes 14 and 10 together.

Likely causes

  1. Gas valve leaking through or closing slowly
  2. Flame sensor wire shorted to ground faking a signal
  3. Control fault sensing flame that is not there

How to fix it — step by step

  1. Treat this as a gas safety fault. Turn the power off and close the gas shutoff to the furnace.
  2. If you smell gas, leave the building and call the gas supplier from outside.
  3. With the gas off, inspect the flame sensor wire for chafed insulation touching metal. Repair any ground short you find.
  4. Confirm the burners are fully out with the valve off. Flame present with the valve off means the valve is leaking.
  5. Do not run the furnace on this code. A leaking gas valve is replaced by a pro, not adjusted.
  6. Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - 14 should stay clear for the whole cycle. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 14 code

Typical pro repair $200–$600

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related Ruud Furnace 801S Series (7 segment display control) error codes

See all Ruud 801S Series (7 segment display control) codes & guides →