Ruud Furnace 801S Series (7 segment display control) 55 Error Code

What the 55 code means

Pressure switch stuck closed when it should be open. The control checks the switch before the inducer starts, and it is already closed.

Likely causes

  1. Pressure switch contacts stuck or welded closed
  2. Water or debris holding the switch closed
  3. Short in the switch wiring

How to fix it — step by step

  1. Turn the power off before opening the blower compartment.
  2. Find the pressure switch near the inducer. It is a round switch with a rubber hose and two wires.
  3. Pull the hose and check for water or debris holding pressure on the switch. Clear the hose and the inducer port.
  4. With the inducer off, test the switch with a meter. Continuity across the switch with no draft means the contacts are stuck.
  5. If wiring is sound and the switch stays closed, replace the pressure switch with the correct setpoint part.
  6. Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - 55 should stay clear for the whole cycle. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 55 code

Parts run $50–$205Typical pro repair $133–$505
  • pressure switch$50–$205Shop at Amazon
  • Tools for this job, if you need them$15–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related Ruud Furnace 801S Series (7 segment display control) error codes

See all Ruud 801S Series (7 segment display control) codes & guides →