Lennox Furnace Lennox Residential Communicating Systems (S30/S40 communicating thermostat, gas furnace) E205 Error Code
What the E205 code means
Gas valve relay contact closed. The furnace gas valve relay contact is closed when it should not be. The relay is located on the furnace control. Lennox lists this alert as 205 in the guide.
Likely causes
- The gas valve relay on the furnace control has failed with its contact closed.
- A wiring fault between the control and the gas valve is holding the circuit.
How to fix it — step by step
- Turn off power and the gas supply before any check, since this fault concerns the gas valve circuit.
- Check the wiring on the control and the gas valve, as the Lennox guide directs. A pinched or shorted wire that explains the closed contact is a wiring repair, not a board replacement.
- If the wiring is sound and the alert continues, Lennox directs replacement of the furnace control, since the relay is on that control. A dealer should do this work. → Shop the furnace control at Amazon
- Verify the fix: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - E205 should stay clear for the whole cycle. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the furnace control.
Parts that commonly fix the E205 code
- furnace controlShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.