What the E273 code means

Flame fail in run mode, Watchguard. The furnace flame is going off during a heating cycle and the system goes into Watchguard mode. Lennox lists this alert as 273 in the guide.

Likely causes

  1. The flame sensor signal is weak, so the control loses flame proof mid cycle.
  2. The burner face is dirty or the unit ground is poor, weakening flame rectification.

How to fix it — step by step

  1. Turn off power and locate the flame sensor. It is a single metal rod in the burner flame path, held by one screw at the burner assembly.
  2. Remove the sensor and clean its rod with fine abrasive pad until the metal is bright. A dull, coated rod reads low flame current, which is exactly this fault.
  3. Refit the sensor, restore power, and run a heat call. A technician can read the flame sensor microamperes through the thermostat or control diagnostics, as the guide directs. A reading that now holds through the whole cycle confirms the sensor surface was the cause.
  4. Measure the voltage from neutral to ground to confirm a good unit ground, per the guide, and clean the face of the burner assembly if the signal is still weak.
  5. If the flame still drops out with a clean sensor and a good ground, replace the flame sensor. A dealer should check gas pressure next if a new sensor does not hold the flame. → Shop the flame sensor at Amazon
  6. Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - E273 should stay clear for the whole cycle. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E273 code

Typical pro repair $150–$250

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.