Lennox Furnace Lennox Residential Communicating Systems (S30/S40 communicating thermostat, gas furnace) E272 Error Code

What the E272 code means

Low pressure switch open in run mode, Watchguard. The furnace low pressure switch opened during run mode and the system goes into Watchguard mode after repeated occurrences. Lennox lists this alert as 272 in the guide.

Likely causes

  1. The vent or condensate drain restricted during the run, dropping inducer pressure.
  2. A pressure switch hose is cracked or the unit is out of level.

How to fix it — step by step

  1. Turn off power to the furnace at its switch and breaker before opening the blower or burner compartment. The pressure switches, hoses, and inducer are inside that compartment.
  2. Inspect the vent piping and the combustion air inducer for blockage or restriction, and check the condensate drain and the drain strainers at the outlet of the cold end heater box. The Lennox guide lists these same checks for this code.
  3. Check the pressure switch hoses for cracks and check that the furnace is level. A cracked hose or a unit out of level that traps condensate produces this code without any switch failure.
  4. Restore power and run a heat call while a technician measures the operating pressure in inches of water column against the low pressure switch rating. Pressure below the rating with a clear vent means the inducer is weak. Pressure at or above the rating with the switch still open means the switch itself has failed.
  5. Replace the part the measurement condemns, either the inducer assembly or the pressure switch, and confirm a full heat call completes with the code clear.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E272 code

No specific replacement part is documented for this fault. If the checks above do not clear it, your furnace likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.