What the E226 code means
High pressure switch stuck closed. The furnace high pressure switch will not open. Lennox lists this alert as 226 in the guide.
Likely causes
- The high pressure switch is stuck closed.
- There is moisture in the pressure switch.
How to fix it — step by step
- Turn off power to the furnace at its switch and breaker before opening the blower or burner compartment. The pressure switches, hoses, and inducer are inside that compartment.
- Inspect the vent piping and the combustion air inducer for blockage or restriction, and check the condensate drain and the drain strainers at the outlet of the cold end heater box. The Lennox guide lists these same checks for this code.
- Check the pressure switch hoses for cracks and check that the furnace is level. A cracked hose or a unit out of level that traps condensate produces this code without any switch failure.
- Restore power and run a heat call while a technician measures the operating pressure in inches of water column against the high pressure switch rating. Pressure below the rating with a clear vent means the inducer is weak. Pressure at or above the rating with the switch still open means the switch itself has failed.
- Replace the part the measurement condemns, either the inducer assembly or the pressure switch, and confirm a full heat call completes with the code clear.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the fault is internal - there is no documented owner fix beyond the steps above. If you're not comfortable taking it apart yourself, a repair shop is the next step.
Parts that commonly fix the E226 code
No specific replacement part is documented for this fault. If the checks above do not clear it, your furnace likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.