What the E252 code means

Discharge air temperature too high, gas heat only. The discharge air temperature is high. Lennox lists this alert as 252 in the guide.

Likely causes

  1. Airflow is too low for the heat being produced, raising the discharge air temperature.
  2. The firing rate is too high for the available airflow.

How to fix it — step by step

  1. Check the air filter first. It is in the return grille or the furnace filter slot. A loaded filter is the most common reason discharge air runs hot.
  2. Replace a loaded filter and check that supply registers are open and return grilles are not blocked. Restored airflow that clears the alert on the next heat call confirms airflow was the cause.
  3. If the filter and registers are clear, a technician should check temperature rise, airflow, and input rate, which are the three checks Lennox lists for this code. A rise still above the rating plate range with good airflow points at the firing rate or the blower setup, which is dealer work.
  4. Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - E252 should stay clear for the whole cycle. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E252 code

No specific replacement part is documented for this fault. If the checks above do not clear it, your furnace likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.