Lennox Furnace Lennox Residential Communicating Systems (S30/S40 communicating thermostat, gas furnace) E274 Error Code
What the E274 code means
Primary limit switch open, Watchguard. The furnace limit switch has been open for more than three minutes and the system goes into Watchguard mode. Lennox lists this alert as 274 in the guide.
Likely causes
- Low supply air from a dirty filter or a duct blockage overheated the furnace.
- High gas pressure or an incorrect firing rate overheated the furnace.
- A zone damper is not functioning, closing off airflow.
How to fix it — step by step
- Check the air filter in the return grille or furnace slot and replace it if it is loaded. Low supply air from a plugged filter is the first cause Lennox lists for this code.
- Walk the supply registers and confirm they are open, and check any zone dampers are opening on a call. A closed damper set starves the furnace of airflow the same way a filter does.
- Restore airflow and run a heat call. A full call with no limit trip confirms airflow was the cause.
- If the limit still opens with verified airflow, a technician should check gas pressure and firing rate, the remaining checks Lennox lists. A limit that opens on correct pressure and rate is itself weak and should be replaced.
- Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - E274 should stay clear for the whole cycle. If it comes back, the repair did not cure it: hand over the unit with the code still set rather than cycling resets.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the limit switch.
Parts that commonly fix the E274 code
- limit switch$5–$35Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.