Lennox Furnace Lennox Residential Communicating Systems (S30/S40 communicating thermostat, gas furnace) E291 Error Code
What the E291 code means
Heat airflow below minimum. The heating airflow is below the minimum required level and the system goes into Watchguard mode. Lennox lists this alert as 291 in the guide.
Likely causes
- A dirty air filter or another airflow restriction cut heating airflow.
- The blower is not performing to its set airflow.
How to fix it — step by step
- Check the air filter in the return grille or furnace slot and replace it if loaded. Lennox lists dirty filters and other airflow restrictions as the first check for this code.
- Check supply registers and return grilles for blockages and clear anything covering them.
- Run a heat call. Airflow restored and the code clear means the restriction was the cause.
- If restrictions are clear and the code returns, the guide directs a blower performance check. A blower that cannot reach its set airflow on a clear duct system is failing and a dealer should replace the motor or module. → Shop the blower motor at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the blower motor.
Parts that commonly fix the E291 code
- blower motor$95–$450Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.