Lennox Residential Communicating Systems (S30/S40 communicating thermostat, gas furnace) Error Codes

Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 18 codes covered.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

CodeWhat it meansCheck first
E202Indoor blower motor and unit size mismatch. The unit size code for the indoor unit and the size of the blower…An incorrect appliance unit size code is selected in the furnace configuration.›
E203Invalid or unset unit size code. The unit size code for the indoor unit has not been selected or is set…The unit size code was never programmed, for example after a control replacement.›
E205Gas valve relay contact closed. The furnace gas valve relay contact is closed when it should not be. The…The gas valve relay on the furnace control has failed with its contact closed.›
E206Gas valve second stage relay fault. The furnace gas valve second stage relay is faulty. The furnace will…The second stage gas valve relay on the furnace control has failed.›
E226High pressure switch stuck closed. The furnace high pressure switch will not open. Lennox lists this alert as…The high pressure switch is stuck closed.›
E252Discharge air temperature too high, gas heat only. The discharge air temperature is high. Lennox lists this…Airflow is too low for the heat being produced, raising the discharge air temperature.›
E272Low pressure switch open in run mode, Watchguard. The furnace low pressure switch opened during run mode and…The vent or condensate drain restricted during the run, dropping inducer pressure.›
E273Flame fail in run mode, Watchguard. The furnace flame is going off during a heating cycle and the system goes…The flame sensor signal is weak, so the control loses flame proof mid cycle.›
E274Primary limit switch open, Watchguard. The furnace limit switch has been open for more than three minutes and…Low supply air from a dirty filter or a duct blockage overheated the furnace.›
E275Flame out of sequence with no flame, Watchguard. The furnace flame is out of sequence and the system goes…The gas valve is leaking gas that ignites or is sensed out of sequence.›
E276Calibration failure, Watchguard. The furnace is not able to calibrate, or the high pressure switch opened or…Vent blockage or inducer restriction prevented pressure switch calibration.›
E291Heat airflow below minimum. The heating airflow is below the minimum required level and the system goes into…A dirty air filter or another airflow restriction cut heating airflow.›
E294Inducer motor overcurrent. There is overcurrent in the furnace inducer motor and the system goes into…The inducer motor bearings are failing, raising its current draw.›
E295Indoor blower over temperature. The indoor blower motor is overheating and has tripped on its internal…The blower motor bearings are failing.›
E311Heat rate reduced to match airflow. The heat firing rate has been reduced to match available airflow, called…Restricted airflow from a dirty filter or an undersized or blocked duct system.›
E312Airflow indoor blower cutback. The indoor blower cannot provide the requested airflow due to excessive static…Total external static pressure has exceeded the capability of the blower motor, which›
E344IFC relay Y1 stuck. A link relay problem, possibly a Y1 relay failure. The relay is located on the integrated…The Y1 relay on the integrated furnace control has failed.›
E345Relay O failure. The O relay on the system component has failed. Either the pilot relay contacts did not…The O relay contacts did not close.›

All Lennox furnace models & codes →

Looking for a part?

Once you know the part you need, browse Lennox Residential Communicating Systems (S30/S40 communicating thermostat, gas furnace) replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.