Lennox Residential Communicating Systems (S30/S40 communicating thermostat, gas furnace) Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 18 codes covered.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Code | What it means | Check first | |
|---|---|---|---|
| E202 | Indoor blower motor and unit size mismatch. The unit size code for the indoor unit and the size of the blower… | An incorrect appliance unit size code is selected in the furnace configuration. | › |
| E203 | Invalid or unset unit size code. The unit size code for the indoor unit has not been selected or is set… | The unit size code was never programmed, for example after a control replacement. | › |
| E205 | Gas valve relay contact closed. The furnace gas valve relay contact is closed when it should not be. The… | The gas valve relay on the furnace control has failed with its contact closed. | › |
| E206 | Gas valve second stage relay fault. The furnace gas valve second stage relay is faulty. The furnace will… | The second stage gas valve relay on the furnace control has failed. | › |
| E226 | High pressure switch stuck closed. The furnace high pressure switch will not open. Lennox lists this alert as… | The high pressure switch is stuck closed. | › |
| E252 | Discharge air temperature too high, gas heat only. The discharge air temperature is high. Lennox lists this… | Airflow is too low for the heat being produced, raising the discharge air temperature. | › |
| E272 | Low pressure switch open in run mode, Watchguard. The furnace low pressure switch opened during run mode and… | The vent or condensate drain restricted during the run, dropping inducer pressure. | › |
| E273 | Flame fail in run mode, Watchguard. The furnace flame is going off during a heating cycle and the system goes… | The flame sensor signal is weak, so the control loses flame proof mid cycle. | › |
| E274 | Primary limit switch open, Watchguard. The furnace limit switch has been open for more than three minutes and… | Low supply air from a dirty filter or a duct blockage overheated the furnace. | › |
| E275 | Flame out of sequence with no flame, Watchguard. The furnace flame is out of sequence and the system goes… | The gas valve is leaking gas that ignites or is sensed out of sequence. | › |
| E276 | Calibration failure, Watchguard. The furnace is not able to calibrate, or the high pressure switch opened or… | Vent blockage or inducer restriction prevented pressure switch calibration. | › |
| E291 | Heat airflow below minimum. The heating airflow is below the minimum required level and the system goes into… | A dirty air filter or another airflow restriction cut heating airflow. | › |
| E294 | Inducer motor overcurrent. There is overcurrent in the furnace inducer motor and the system goes into… | The inducer motor bearings are failing, raising its current draw. | › |
| E295 | Indoor blower over temperature. The indoor blower motor is overheating and has tripped on its internal… | The blower motor bearings are failing. | › |
| E311 | Heat rate reduced to match airflow. The heat firing rate has been reduced to match available airflow, called… | Restricted airflow from a dirty filter or an undersized or blocked duct system. | › |
| E312 | Airflow indoor blower cutback. The indoor blower cannot provide the requested airflow due to excessive static… | Total external static pressure has exceeded the capability of the blower motor, which | › |
| E344 | IFC relay Y1 stuck. A link relay problem, possibly a Y1 relay failure. The relay is located on the integrated… | The Y1 relay on the integrated furnace control has failed. | › |
| E345 | Relay O failure. The O relay on the system component has failed. Either the pilot relay contacts did not… | The O relay contacts did not close. | › |
All Lennox furnace models & codes →
Looking for a part?
Once you know the part you need, browse Lennox Residential Communicating Systems (S30/S40 communicating thermostat, gas furnace) replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.