Heil Furnace N9MP (ICP) 6 flashes

What it should look like on your machine

then it repeats

6 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Failure to ignite, or flame sense lost while running. The control is still in its retry sequence and has not yet locked out.

Likely causes

  1. Gas supply off, such as a closed shutoff, so the igniter cycles with no gas
  2. Failed or cracked igniter
  3. Dirty flame sensor so flame lights but is not proved
  4. Low gas pressure

How to fix it — step by step

  1. Turn the power off and close the gas shutoff before working inside the furnace, then confirm the shutoff is actually open for the test. The manual walks through this exact case: with gas shut off, the control tries 4 ignition cycles flashing code 6 before lockout.
  2. Find the igniter in front of the burners and check it for cracks. During a call for heat it should glow red hot for about 22 seconds per try.
  3. If the igniter glows and gas is on but flame is not proved, remove and clean the flame sensor rod with fine steel wool. The manual spec is 0.7 microamps minimum flame sense, with 2.0 to 4.0 normal.
  4. If the igniter never glows, test it with a meter. An open igniter has failed and is replaced.
  5. If gas, igniter, and sensor all check out and code 6 continues, call a pro to check gas pressure and the gas valve.
  6. Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - the furnace should complete the cycle with no code returning. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $150–$500

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related Heil Furnace N9MP (ICP) problems