Heil Furnace N9MP (ICP) 2 flashes

What it should look like on your machine

then it repeats

2 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Pressure switch closed when it should be open. The control checks the switch before the inducer starts and finds it already closed.

Likely causes

  1. Pressure switch contacts stuck closed
  2. Water or debris in the switch hose
  3. Short in the switch wiring

How to fix it — step by step

  1. Turn the power off before opening the cabinet.
  2. Find the pressure switch near the inducer. It is a round switch with a rubber hose and two wires.
  3. Pull the hose, check it for water or debris, and clear the inducer housing port.
  4. With the inducer off, test the switch with a meter. Continuity with no draft means the contacts are stuck.
  5. Repair damaged wiring. If the switch stays closed with a clear hose, replace it with the correct setpoint part.
  6. Verify the fix: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - the furnace should complete the cycle with no code returning. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $50–$205Typical pro repair $133–$505
  • pressure switch$50–$205Shop at Amazon
  • Tools for this job, if you need them$15–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related Heil Furnace N9MP (ICP) problems

See all Heil N9MP (ICP) codes & guides →