Heil Furnace N9MP (ICP) 6 + 1 flashes

What it should look like on your machine

then it repeats

1 flash - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Soft lockout. The maximum trials for ignition were reached, with a 3 hour delay before the control tries again.

Likely causes

  1. Same causes as code 6, still present after all retries
  2. Gas supply problem not corrected
  3. Igniter or flame sensor fault not corrected

How to fix it — step by step

  1. Read the code as two parts: six short flashes, then one long flash. This is the lockout that follows code 6, not a new fault.
  2. Work through the code 6 checks first: gas supply on, igniter glowing, flame sensor clean.
  3. Do not keep power cycling to force retries. The control waits 3 hours in this lockout while the heat call remains, and a power reset clears it, but the furnace will lock out again if the cause is still there.
  4. If the cause is not gas supply, igniter, or sensor, call a pro. The remaining suspects are gas pressure and the gas valve.
  5. Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - the furnace should complete the cycle with no code returning. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $150–$500

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.