Heil Furnace N9MP (ICP) 3 flashes
What it should look like on your machine
then it repeats
3 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Pressure switch open when it should be closed. The inducer runs but the switch never proves draft, so ignition is blocked.
Likely causes
- Blocked vent or combustion air pipe
- Pressure switch hose off, cracked, or plugged
- Weak or failed inducer motor
- Failed pressure switch
How to fix it — step by step
- Turn the power off before opening any panel.
- Find the pressure switch by the inducer and inspect its hose end to end. Reconnect or replace a bad hose and clear the inducer port.
- Check the vent and intake pipes and the outdoor terminations for blockage.
- Restore power and call for heat. If the inducer does not start, the fault is the inducer or its power, not the switch.
- If the inducer runs strong and the vent is clear, test the switch during the run. No closure under proven draft means the switch failed.
- Replace the switch with the correct setpoint part. Weak draft itself is inducer or vent work for a pro.
- Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - the furnace should complete the cycle with no code returning. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the pressure switch.
Shop the pressure switch at Amazon
Also tied to this fault: inducer motor - Shop at Amazon
Parts that commonly fix it
- pressure switch$50–$205Shop at Amazon
- inducer motor$50–$215Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.