Heil N9MP (ICP) Common Problems
Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 11 problems covered.
Not sure of the code? Tap along with it
If your Heil Furnace blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.
Your taps: -
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Problem | What it means | Check first | |
|---|---|---|---|
| 10 flashes | Line voltage polarity reversed. The 115 volt supply to the furnace has line and neutral swapped. | Line and neutral swapped at the furnace junction box | › |
| 2 flashes | Pressure switch closed when it should be open. The control checks the switch before the inducer starts and… | Pressure switch contacts stuck closed | › |
| 3 flashes | Pressure switch open when it should be closed. The inducer runs but the switch never proves draft, so… | Blocked vent or combustion air pipe | › |
| 4 flashes | Limit or rollout switch open for less than 2 minutes. A safety switch in the limit circuit opened, most often… | Dirty filter or restricted ducts overheating the furnace | › |
| 5 flashes | Flame sensed out of sequence. The control sees flame when the gas valve should be closed. | Gas valve leaking through or closing slowly | › |
| 6 + 1 flashes | Soft lockout. The maximum trials for ignition were reached, with a 3 hour delay before the control tries… | Same causes as code 6, still present after all retries | › |
| 6 flashes | Failure to ignite, or flame sense lost while running. The control is still in its retry sequence and has not… | Gas supply off, such as a closed shutoff, so the igniter cycles with no gas | › |
| 7 flashes | Soft lockout. The limit or rollout switch stayed open longer than 2 minutes, with a one hour delay. The… | Limit circuit fault from code 4 that never cleared | › |
| 8 flashes | Permanent lockout. The gas valve relay contact is stuck closed, or the gas valve is miswired. Only a power… | Gas valve relay contact on the control stuck closed | › |
| LED off | No power to the control. Either 24 volt or 115 volt power is off, or the board fuse is open. | 115 volt or 24 volt power off at the switch or breaker | › |
| LED on solid | Soft lockout from a furnace control error, with a one hour delay. The control has stopped itself. | Internal error inside the furnace control | › |
All Heil furnace models & codes →
Once you know the part you need, browse Heil N9MP (ICP) replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.