Heil Furnace N9MP (ICP) 5 flashes

What it should look like on your machine

then it repeats

5 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Flame sensed out of sequence. The control sees flame when the gas valve should be closed.

Likely causes

  1. Gas valve leaking through or closing slowly
  2. Flame sensor wire shorted to ground
  3. Flame present from a valve that did not seat

How to fix it — step by step

  1. Turn the power off and close the gas shutoff to the furnace. Flame out of sequence is a safety fault.
  2. If you smell gas, leave the building and call the gas supplier from outside.
  3. With the gas off, inspect the flame sensor wire for chafed insulation touching the cabinet and repair any short.
  4. Confirm the burners are fully out with the valve off. Flame still present means the valve leaks.
  5. Do not run the furnace on this code. A leaking gas valve is replaced by a pro.
  6. Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - the furnace should complete the cycle with no code returning. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $200–$600

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.