Goodman Furnace Newer single-stage — alphanumeric display control (RS6621008) EE2 Error Code

What the EE2 code means

Pressure switch circuit not closed when it should be on newer Goodman single-stage furnaces with the alphanumeric display control. Draft was not proven, so ignition does not proceed.

Likely causes

  1. blocked vent or intake pipe
  2. clogged condensate drain
  3. weak inducer motor → Shop the inducer motor at RepairClinic
  4. blocked or pinched pressure switch hose → Shop the pressure switch at RepairClinic

How to fix it — step by step

  1. Check the thermostat is set to Heat and calling for heat
  2. Check the outdoor vent and intake pipes are clear of snow, ice or debris
  3. On a high-efficiency model, check the condensate drain line and trap are not clogged or frozen
  4. Turn power off at the furnace switch for 30 seconds, then back on, and try one heat call
  5. If the code returns, stop resetting and call a licensed HVAC technician

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the EE2 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Goodman manual is on Goodman's support site — you'll need your model number.

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related Goodman Furnace Newer single-stage — alphanumeric display control (RS6621008) error codes

See all Goodman Newer single-stage — alphanumeric display control (RS6621008) codes & guides →