Goodman Furnace Newer single-stage — alphanumeric display control (RS6621008) EE1 Error Code
What the EE1 code means
Pressure switch circuit closed at the start of a heat cycle on newer Goodman single-stage furnaces with the alphanumeric display control. The switch should be open before the inducer starts.
Likely causes
- sticking pressure switch contacts → Shop the pressure switch at RepairClinic
- short in pressure switch wiring
- water in the pressure switch hose
How to fix it — step by step
- Check the thermostat is set to Heat and calling for heat
- Check the outdoor vent and intake pipes are clear of snow, ice or debris
- On a high-efficiency model, check the condensate drain line and trap are not clogged or frozen
- Turn power off at the furnace switch for 30 seconds, then back on, and try one heat call
- If the code returns, stop resetting and call a licensed HVAC technician
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the pressure switch.
Parts that commonly fix the EE1 code
- pressure switch - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Goodman manual is on Goodman's support site — you'll need your model number.
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related Goodman Furnace Newer single-stage — alphanumeric display control (RS6621008) error codes
See all Goodman Newer single-stage — alphanumeric display control (RS6621008) codes & guides →