GE Dryer Profile DPVH890 Series E5 Error Code
What the E5 code means
On GE Profile DPVH890 dryers (technical service manual): Outlet Open - the outlet thermistor circuit is open; check and replace if necessary.
Likely causes
- Open/failed outlet thermistor → Shop the outlet thermistor at RepairClinic
- Disconnected thermistor connector
- Broken wire in the thermistor harness → Shop the wire harness at RepairClinic
How to fix it — step by step
- Unplug the dryer and let it cool
- Try one cycle after restoring power
- If E5 returns, arrange service for thermistor/harness replacement
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the outlet thermistor.
Shop the outlet thermistor at RepairClinic or Amazon
Also tied to this fault: wire harness - Shop at RepairClinic or Amazon
Parts that commonly fix the E5 code
- outlet thermistor - Shop at RepairClinic or Amazon
- wire harness - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official GE manual is on GE's support site — you'll need your model number.
Find your model number inside the door on the frame. It's the key to the right manual pages and the right parts.